EXT15H II Outdoor High Water Alarm

EXT15H II Outdoor High Water Alarm
Click Below For More Images:
  • EXT15H II Outdoor High Water Alarm
  • EXT15H II Outdoor High Water Alarm
  • EXT15H II Outdoor High Water Alarm
  • EXT15H II Outdoor High Water Alarm
on sale Get Extra Savings Today!
Price:
199.00149.99
or Click to Customize or Scroll Down to Select Options
>> Get a Quote for a EXT15H II Outdoor High Water Alarm
In Stock. Normally Ships Same Day to 48 hours. Contact us if urgent.
VN:F [1.9.22_1171]
(Click stars to rate)
Rating: 0.0/10 (0 votes cast)

The EXT15H II Outdoor High Water Alarm will sound an 85 db alarm buzzer and illuminate a 360° red beacon light whenever high water is detected. The outdoor high water alarm provides a convenient automatic reset. The Conery EXT15H II high level alarm includes a handy silence button and individual test button. The outdoor high water alarm comes standard with a 15’ mechanical float and can control up to 3/4 HP Pump with the provided switch / contacts.

The EXT15H II Outdoor High Water Alarm applications include: sump pump alarm, pump station alarm, lift station alarm. The EXT15H II Outdoor High Water Alarm also functions as a grinder pump alarm, aerator system alarm, septic system alarm, pump pit alarm, pond level alarm and similar high level alarm applications.

Conery EXT15H II Outdoor High Water Alarm

Rating by Aqua Technology Group: 5.0 stars – 29 March 2016

*****

Excellent Outdoor High Water Level Alarm. Perfect for us as an aerator system alarm with pump control, septic system alarm, septic tank alarm, sump pump alarm, pump pit alarm, irrigation or pond level control / alarm.

  • NEMA Type 4X rated for outdoor use
  • UL Rated
  • Non-metallic / Polycarbonate enclosure (6″ x 4” x 3” trade size)
  • Overall Dimensions: 8-3/4″ H x 6-1/4″ W x 4-5/8″ D
  • High / Low Water Alarm & Pump Control
  • 95 db alarm buzzer (rated 85 db @ 10′)
  • 120 VAC electrical rating
  • Auxiliary contacts- Rated 5 A @ 230 VAC Max
  • Controls up to a 3/4 HP Pump (115V, 3/4 HP, 15.0 A. (FLA))
  • 15’ mechanical float standard
  • No Power Cord – for hardwire applications using included terminal block (use the JB15H II Alarm if you need a corded alarm setup)
  • Alarm Test / Normal /Silence Switch
  • Two Year Limited Warranty
  • Available in both High Water and Low Level Alarm Versions
  • Available in both Pump Down and Pump Up Versions
  • Made in the USA
  • Custom Cable Lengths (Use Dropdown List Below or Contact Us for other lengths)
  • No Float Options
  • Mercury Float Options – Note: We cannot ship mercury type float switches to the following states: California, Connecticut, Illinois, Louisiana, Maine, Massachusetts, Minnesota, New Hampshire, New York, Rhode Island, Vermont, Washington, Wisconsin. Please select the mechanical versions to avoid shipping delays.

Conery Mfg Inc warrants to the original consumer that this product shall be free from manufacturing defects for two years after the date of manufacture. During that time period and subject to the conditions set forth below, Conery Mfg Inc will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of Conery Mfg Inc.

This warranty does not apply to the misapplication of the products, defects or malfunctions resulting from failure to properly install, operate, or maintain the unit in accordance with the manufacturers instructions, failures resulting from abuse, misuse, accident, or negligence of the product, damage due to lightning or other “Acts of God,” or units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices.
Warranty is void if installation, service, or repair of any component of the product is performed by anyone other than a licensed electrician or other qualified service personnel.
It is the full responsibility of the original consumer to return defective product or component at their own expense. The consumer shall take full responsibility for the removal, shipping, and reinstallation of the product or component.To return a product under warranty, the original consumer should contact Conery Mfg Inc by telephone and request an RGA (Return Goods Authorization) form. It is the responsibility of the consumer to fill out, in completion, the form and return it with the defective products to Conery Mfg Inc. Conery Mfg Inc may also include a 15% restocking fee for non-defective products that were incorrectly ordered by the consumer.
Any implied warranties of merchantability or fitness are limited to the duration of this written warranty. Conery Mfg Inc shall not, in any manner, be liable for any incidental or consequential damages as a result of a breach of this written warranty or any implied warranty.
Conery Mfg Inc reserves the right to change any and all of the information contained in this warranty with no prior notice.


About Conery Mfg.

Located in Ashland, Ohio, Conery Mfg Inc was founded by Scott Conery in 1979. Today, Conery proudly continues to manufacture their very first product, the #2900 series float switch, here in the United States. Conery Mfg Inc consistently strives to produce the highest quality products in the wastewater market and look forward to serving you both today and into the future.


Select options below. Need Help? Call us 24/7 at 1-800-513-8993

Shipping Note
We cannot ship outdoor high water alarms with the optional mercury type float switches to the following states: California, Connecticut, Illinois, Louisiana, Maine, Massachusetts, Minnesota, New Hampshire, New York, Rhode Island, Vermont, Washington, Wisconsin. Please select the standard mechanical versions to avoid shipping delays.
199.00149.99
Get Extra Savings Today!

Shipping is calculated in the Cart

In Stock. Normally Ships Same Day to 48 hours. Contact us if urgent.

Currency Conversion

More Buying Options:

Not ready to buy? Buying in Bulk? Government Buyer? Get a Quote for a EXT15H II Outdoor High Water Alarm
Make Us an Offer!

Additional Product Information:

↑ Top of Page
×
Quick Quote
  • This field is for validation purposes and should be left unchanged.
×
My Favorites

< ?php mfp_the_link("add_link=Add item to favorites”);
?>
< ?php mfp_display("Your Favorites”);
?>

×
×